Multifunction Testers
Multifunction testers or MFTs are handheld versatile devices used to verify the safety of electrical installations in domestic, commercial, and industrial settings. These installation testers are designed to streamline and simplify electrical testing processes and ensure that fixed wiring is safe and correctly installed to meet relevant local standards and safety requirements
Multifunctio...
Showing 1-20 of 135 products
RS Pro
Automotive Relay Tester
-
-
-
-
-
-
-
-
-
-
-
-
-
Auto Test
-
-
-
-
-
-
-
-
-
68mm
30mm
185g
128mm
-
CE
-
-
No
-
-
-
Battery
-
-
-
-
-
-
-
-
-
-
-
-
RS Pro
Automotive Current Tester
-
-
No
-
-
-
-
-
-
-
48V
-
-
Auto Test
-
-
-
-
-
-
-
-
-
86mm
28.5mm
68g
37mm
-
CE
-
-
No
-
-
-
Battery
-
-
-
-
-
LCD Backlight
-
-
-
-
-
-
RS Pro
Multifunction Tester
-
Phase to Earth
Yes
Yes
-
MT-6600
Yes
-
1000V
-
1000V
-
-
Multifunction Installation Tester
Yes
-
-
WiFi, Bluetooth
1mA
-
15h
AC Selective, General
-
242mm
105mm
1.6kg
145mm
-
CE
IP65
-
No
-
-
45°C
Battery
-
-
-
-
-
LCD
-
-
-
-
-
CAT III
RS Pro
Multifunction Tester
-
Phase to Earth
Yes
Yes
-
MT-6600
Yes
-
1000V
-
1000V
-
-
Multifunction Installation Tester
Yes
-
-
WiFi, Bluetooth
1mA
-
15h
AC Selective, General
-
242mm
105mm
1.6kg
145mm
-
CE
IP65
-
No
-
RSCAL
45°C
Battery
-
-
-
-
-
LCD
-
-
-
-
-
CAT III
RS Pro
Multifunction Tester
-
Phase to Earth
Yes
Yes
-
MT-6600
Yes
-
1000V
-
1000V
-
-
Multifunction Installation Tester
Yes
-
-
WiFi, Bluetooth
1mA
-
15h
AC Selective, General
-
242mm
105mm
1.6kg
145mm
-
CE
IP65
-
No
-
UKAS
45°C
Battery
-
-
-
-
-
LCD
-
-
-
-
-
CAT III
RS Pro
Multifunction Tester
-
Phase to Earth
Yes
Yes
-
MT-6600
Yes
-
1000V
-
1000V
-
-
-
-
-
-
Bluetooth
1mA
-
15h
-
-
242mm
105mm
1.6kg
145mm
-
BS EN 615576, CE
IP67
-
No
-
-
45°C
Battery
-
-
-
-
-
LCD
-
-
-
-
-
CAT III
Fluke
-
3 Wire
-
-
-
1651B
-
-
Yes
-
250 V, 500 V, 1000 V
-
500V ac
Continuity, Wiring Polarity
-
-
-
UK Mains
-
-
200mA
-
-
AC Type
-
-
-
-
-
-
-
BS 7671, EN 61010-I, HD 384, IEC 60364
-
IP40
-
-
-
100 x 250 x 125mm
CAT III 500 V, CAT IV 300 V
2000Ω
20Ω
CAT III, CAT IV
-
-
-
Battery, Mains
250mm
125mm
-
Fluke
-
3 Wire
-
-
-
1653B
-
-
Yes
-
50 V, 100 V, 250 V, 500 V, 1000 V
-
500V ac
Continuity, Wiring Polarity
-
-
-
-
-
-
200mA
-
-
AC Type
-
-
-
-
-
-
-
EN 61010-I, HD 384, IEC 60364
-
IP40
-
-
-
100 x 250 x 125mm
CAT III 500 V, CAT IV 300 V
2000Ω
20Ω
CAT III, CAT IV
-
-
-
Battery, Mains
250mm
125mm
-
Fluke
Multifunction Tester
-
High/Low Current
Yes
Yes
-
Fluke 1663
No
-
1000V
-
500V
-
-
Installation
Yes
Yes
-
IR USB
-
-
-
Type G, AC, Type S
-
10cm
25cm
1.3kg
12.5cm
Yes
ANSI/ISA -s82.02.01 and CAN/CSA c22.2 No. 1010, UL61010, Complies IEC/EN610101
IP40
-
IEC 60364, all relevant local Standard
-
-
40°C
Battery
-
-
-
-
-
-
-
-
-
-
-
CAT IV 300 V, Philips
Fluke
Multifunction Tester
-
2 Wire, 3 Wire, Phase to Earth, Phase to Neutral
Yes
Yes
-
-
Yes
-
1000, 50V
-
600V
-
-
-
Yes
Yes
-
USB
10mA
-
-
-
-
2625000.00mm
14.19cm
1.6kg
11.93cm
Yes
IEC 610102034, IEC/EN 610101, IEC 610102030
IP40
-
-
-
-
-
Lithium-ion Battery
-
-
-
-
-
Touch Screen
-
-
-
-
-
CAT III 600 V CAT IV 300 V
Fluke
Multifunction Tester
-
Phase to Earth, 2 Wire, 3 Wire, Phase to Neutral
Yes
Yes
-
-
Yes
-
1000, 50V
-
600V
-
-
-
Yes
Yes
-
USB
10mA
-
-
-
-
2625000.00mm
14.19cm
1.6kg
11.93cm
-
IEC 610102030, IEC 610102034, IEC/EN 610101
IP40
-
-
-
-
-
Lithium-ion Battery
-
-
-
-
-
Touch Screen
-
-
-
-
-
CAT III 600 V CAT IV 300 V
Fluke
Multifunction Tester
-
2 Wire, 3 Wire, Phase to Earth, Phase to Neutral
Yes
Yes
-
-
Yes
-
1000, 50V
-
600V
-
-
-
Yes
Yes
-
USB
10mA
-
-
-
-
2625000.00mm
14.19cm
1.6kg
11.93cm
Yes
IEC 610102034, IEC/EN 610101, IEC 610102030
IP40
-
-
-
RSCAL
-
Lithium-ion Battery
-
-
-
-
-
Touch Screen
-
-
-
-
-
CAT III 600 V CAT IV 300 V
Fluke
Multifunction Tester
-
Phase to Earth, 2 Wire, 3 Wire, Phase to Neutral
Yes
Yes
-
-
Yes
-
1000, 50V
-
600V
-
-
-
Yes
Yes
-
USB
10mA
-
-
-
-
2625000.00mm
14.19cm
1.6kg
11.93cm
-
IEC 610102030, IEC 610102034, IEC/EN 610101
IP40
-
-
-
RSCAL
-
Lithium-ion Battery
-
-
-
-
-
Touch Screen
-
-
-
-
-
CAT III 600 V CAT IV 300 V
Fluke
Multifunction Tester
-
2 Wire, 3 Wire, Phase to Earth, Phase to Neutral
Yes
Yes
-
-
Yes
-
1000, 50V
-
600V
-
-
-
Yes
Yes
-
USB
10mA
-
-
-
-
2625000.00mm
14.19cm
1.6kg
11.93cm
Yes
IEC 610102034, IEC/EN 610101, IEC 610102030
IP40
-
-
-
UKAS
-
Lithium-ion Battery
-
-
-
-
-
Touch Screen
-
-
-
-
-
CAT III 600 V CAT IV 300 V
Fluke
Multifunction Tester
-
Phase to Earth, 2 Wire, 3 Wire, Phase to Neutral
Yes
Yes
-
-
Yes
-
1000, 50V
-
600V
-
-
-
Yes
Yes
-
USB
10mA
-
-
-
-
2625000.00mm
14.19cm
1.6kg
11.93cm
-
IEC 610102030, IEC 610102034, IEC/EN 610101
IP40
-
-
-
UKAS
-
Lithium-ion Battery
-
-
-
-
-
Touch Screen
-
-
-
-
-
CAT III 600 V CAT IV 300 V
Gossen Metrawatt
Multifunction Tester
-
2 Wire
Yes
Yes
-
M520F
-
-
9V dc
-
-
-
-
-
Yes
-
-
USB
-
-
-
-
-
-
-
-
-
-
No
IP40
-
-
-
-
40°C
-
-
-
-
-
-
-
-
-
-
-
-
-
Kewtech Corporation
Multifunction Tester
-
High Current
Yes
Yes
-
KT63DL
Yes
-
1000V
-
1000V
-
-
Polarity, RCD, Insulation, Loop, CPE
No
-
-
-
200mA
-
-
-
-
313mm
2mm
2.32kg
2mm
-
No
IP54
-
-
-
-
-
Battery Power Supply
-
-
-
-
-
-
29.99kΩ
9.99Ω
-
-
-
-
Kewtech Corporation
Multifunction Tester
-
2 Wire, 3 Wire
Yes
Yes
-
KT66DL
Yes
-
1000V
-
600V
-
-
PAT, Continuity, Straight, Phase Rotation, Insulation, Bent Monopole, Earth Resistance, RCD, Voltage, Loop
No
-
-
USB
200mA
-
-
AC, Type A
-
136mm
235mm
1.3kg
114mm
Yes
IEC 61010-Tester -2-030-2-034, IEC61557-1, IEC 61010-1 CATIV (300V) CATIII (600V) pollution degree 2, IEC 60529 IP40, 10, EN 61326-2-2 (EMC)
IP40
-
EN 61326-2-2 (EMC), IEC 60529 IP40, IEC 61010-1, IEC 61557-1,2,3,4,5,6,7,10, BS7671- 18th Edition
-
-
-
Battery Power Supply
-
-
-
-
-
3.5 in Colour LCD Touch Screen
-
-
-
-
-
CAT III 600 V, CAT IV 300 V
Martindale
Multifunction Tester
-
4 Wire, 3 Wire
Yes
Yes
-
ET6000
Yes
-
500V
-
500V
-
-
Insulation Resistance, Continuity, Fault Loop Impedance, Earth Resistance, RCD
Yes
Yes
-
-
200mA
-
-
Type B, F, AC, Type A, B+, Type G
-
25mm
107mm
1.3kg
135mm
Yes
18th Edition, BS 57671:2018, BS EN 61010-1, BS EN 61326-1, BS EN 61557
-
-
18th Edition, BS EN 61010-1, BS 57671:2018, BS EN 61326-1, BS EN 61557
-
-
-
AA Batteries / rechargeable Batteries
-
-
-
-
-
Backlight
-
-
-
-
-
CAT IV, CAT III
Martindale
Multifunction Tester
-
4 Wire, 3 Wire
Yes
Yes
-
ET6000
Yes
-
500V
-
500V
-
-
Insulation Resistance, Continuity, Fault Loop Impedance, Earth Resistance, RCD
Yes
Yes
-
-
200mA
-
-
Type B, F, AC, Type A, B+, Type G
-
25mm
107mm
1.3kg
135mm
Yes
18th Edition, BS 57671:2018, BS EN 61010-1, BS EN 61326-1, BS EN 61557
-
-
18th Edition, BS EN 61010-1, BS 57671:2018, BS EN 61326-1, BS EN 61557
-
RSCAL
-
AA Batteries / rechargeable Batteries
-
-
-
-
-
Backlight
-
-
-
-
-
CAT IV, CAT III
...