RCCBs
An RCCB or residual-current circuit breaker is a safety device used to protect electrical circuits. RCCBs protect people from electric shocks, and electrocution and help prevent electrical fires.
RS offers an extensive range of high-performance RCCBs and RCDs from leading brands including ABB, Schneider Electric, and Siemens.
How does an RCCB work?
An RCCBs incoming current ...
Showing 1-20 of 1759 products
RS Pro
Residual Current Circuit Breaker
-
-
16A
-
2
-
NF12
-
10mA
-
-
DIN Rail
Type A
-
-
-
EN 60715, CSA, IEC/EN 60204, IEC/EN 60947-2, UL 508, IEC/EN 60947-5-1, IEC/EN 60947-4-1
Screw
-
70mm
85mm
-
-
-
-
-
-
Type A
-
230V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
25A
-
2
-
NF12
-
30mA
-
-
DIN Rail
Type A
-
-
35 mm
IEC/EN60044-8 & IEC/EN61869-2
-
-
70mm
85mm
-
-
-
-
-
-
Type A
-
230V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
25A
-
2
-
NF12
-
300mA
-
-
DIN Rail
Type A
-
-
-
IEC 6951 to 850°C and IEC 695, EN 609981: 004, EN 6051: 00 A: 006 (S.C. 0..), UL94 V, RoHS, IECEN 6069511
Screw
-
70mm
85mm
-
-
-
-
-
-
Type A
-
230V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
40A
-
2
-
NF12
-
30mA
-
-
DIN Rail
Type A
-
-
-
IEC/EN 61008, CE, VDE
-
-
70mm
85mm
-
-
-
-
-
-
Type A
-
230V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
40A
-
2
-
NF12
-
300mA
-
-
DIN Rail
Type A
-
-
-
IEC/EN 61008, CE, VDE
-
-
70mm
85mm
-
-
-
-
-
-
-
-
230V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
63A
-
2
-
NF12
-
30mA
-
-
DIN Rail
Type A
-
-
-
RoHS
-
90mm
70mm
85mm
-
-
-
-
-
-
Type A
-
230V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
25A
-
4
-
NF14
-
30mA
-
-
DIN Rail
Type A
-
-
-
CE, IEC/EN 61008, VDE
-
68mm
70mm
85mm
-
-
-
-
-
-
Type A
-
400V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
40A
-
4
-
NF14
-
30mA
-
-
DIN Rail
Type A
-
-
-
IEC/EN 61008, CE, VDE
-
68mm
70mm
85mm
-
-
-
-
-
-
Type A
-
400V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
40A
-
4
-
NF14
-
30mA
-
-
DIN Rail
Type B
-
-
-
VDE, IEC/EN 61008, CE
-
73.5mm
70mm
85mm
-
-
-
-
-
-
Type B
-
400V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
40A
-
4
-
NF14
-
300mA
-
-
DIN Rail
Type A
-
-
-
CE, IEC/EN 61008, VDE
-
68mm
70mm
85mm
-
-
-
-
-
-
Type A
-
400V ac
-
-
RS Pro
Residual Current Circuit Breaker
-
-
63A
-
4
-
NF14
-
30mA
-
-
DIN Rail
Type A
-
-
-
EN60947, RoHS
-
90mm
145mm
220mm
-
-
-
-
-
-
Type A
-
400V ac
-
-
Schneider Electric
Residual Current Circuit Breaker
-
-
40A
-
4
-
Multi9 ID
Multi9
30mA
-
-
Clip-on, DIN Rail
Instantaneous
-
-
-
EN/IEC 61008-1
Tunnel Type Terminal
-
72mm
81mm
400A
-
Independent Of Power Supply Voltage
-
-
Toggle
A-SI
-
415V ac
-
-
Schneider Electric
Residual Current Circuit Breaker
-
-
63A
-
2
-
IID
Acti9
30mA
-
-
DIN Rail
Voltage Independent
-
-
-
EN/IEC 61008-1
Ferrule
73.5mm
36mm
91mm
1500A
-
Residual Current
-
-
Toggle
Type A
Protection
110V
-
Instantaneous
Siemens
Circuit Breaker
-
-
25A
-
2
-
5SV4
-
10mA
-
-
DIN Rail
AC
-
-
-
UL
Screw Terminal
70mm
36mm
90mm
10kA
-
Snap Action
-
-
-
-
-
230V ac
-
-
Eaton
Residual Current Circuit Breaker
-
-
100A
-
4
-
PDIM
xPole
1mA
-
-
DIN Rail
Type A
-
-
-
DINEN 600, RoHS
Twin-Purpose Terminal
80mm
70mm
65.5mm
-
-
-
-
-
-
-
-
400V ac
-
Non-Delayed
Eaton
Residual Current Circuit Breaker
-
-
25A
-
2
-
PFIM
xPole
30mA
-
-
DIN Rail
Type F, Type G
-
-
-
IEC/EN 62423, ÖVE E 8601, IEC/EN 61008
-
76mm
70mm
80mm
500A
-
Residual Current
-
-
-
F
-
230V ac
-
40 ms
Eaton
Residual Current Circuit Breaker
-
-
25A
-
2
-
PFIM
xPole
300mA
-
-
DIN Rail
Type F, Type G
-
-
-
IEC/EN 62423, ÖVE E 8601, IEC/EN 61008
-
76mm
35mm
80mm
500A
-
Residual Current
-
-
-
-
-
230V ac
-
-
Eaton
Residual Current Circuit Breaker
-
-
25A
-
4
-
PFIM
xPole
30mA
-
-
DIN Rail
Type F, Type G
-
-
-
RoHS IECEN 61008 IECEN 64 ÖVE E 8601
-
76mm
70mm
80mm
500A
-
-
-
-
-
-
-
400V ac
-
-
Eaton
Residual Current Circuit Breaker
-
-
25A
-
4
-
PFIM
xPole
300mA
-
-
DIN Rail
Type F, Type S
-
-
-
IEC/EN 62423, IEC/EN 61008
Lift
80mm
70mm
76mm
500A
-
-
-
-
-
-
-
400V ac
-
40 ms
...