Technical Document
Specifications
Brand
Phoenix ContactNumber of Channels
1
Module Type
Repeater power supply
Barrier Type
Galvanic Barrier
Output Signal Type
Current
Maximum Voltage
125 V dc, 253V ac
Interface
HART
Hazardous Area Certification
ATEX
Input Signal Type
Current
Safety Current Resistance
600Ω
Maximum Current
93mA
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Supply Voltage
19.2 → 30V dc
Safety Current Maximum
93mA
Safety Voltage Maximum
125 V dc, 253 V ac
Series
MACX MCR-EX-SL-RPSSI
Operating Temperature Range
-20 → +60°C
Country of Origin
Germany
Product details
Ex-i Repeater Power Supply and Input Isolation Amplifier, HART
Phoenix Contact brings you a brilliant Ex I repeater power supply and input signal conditioner. This signal conditioner has an integrity rating of SIL 2 (safety integrity level), official zone 2 installation support and bidirectional HART transmission. The 2865340 has been specifically designed for intrinsically safe and electrically isolated operation of measuring transducers and mA current sources installed in hazardous areas.
Features and benefits:
- 1 Channel
- 0.4 mA up to 20mA Input – Intrinsically safe in a powered and non-powered state
- Bidirectional HART transmission
- SIL 2 integrity
- Simply DIN Rail mounted
- 3-way electrical isolation
- Low power dissipation & high transmission accuracy
Intrinsic safety:
The 2865340 was designed to be used in intrinsically safe circuits. EX zone 0 and EX zone 20.
Accessories:
Approvals
CE-compliant
Stock information temporarily unavailable.
Please check again later.
SR 1,577.67
Each (ex VAT)
SR 1,814.32
Each (inc. VAT)
1
SR 1,577.67
Each (ex VAT)
SR 1,814.32
Each (inc. VAT)
1
Technical Document
Specifications
Brand
Phoenix ContactNumber of Channels
1
Module Type
Repeater power supply
Barrier Type
Galvanic Barrier
Output Signal Type
Current
Maximum Voltage
125 V dc, 253V ac
Interface
HART
Hazardous Area Certification
ATEX
Input Signal Type
Current
Safety Current Resistance
600Ω
Maximum Current
93mA
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Supply Voltage
19.2 → 30V dc
Safety Current Maximum
93mA
Safety Voltage Maximum
125 V dc, 253 V ac
Series
MACX MCR-EX-SL-RPSSI
Operating Temperature Range
-20 → +60°C
Country of Origin
Germany
Product details
Ex-i Repeater Power Supply and Input Isolation Amplifier, HART
Phoenix Contact brings you a brilliant Ex I repeater power supply and input signal conditioner. This signal conditioner has an integrity rating of SIL 2 (safety integrity level), official zone 2 installation support and bidirectional HART transmission. The 2865340 has been specifically designed for intrinsically safe and electrically isolated operation of measuring transducers and mA current sources installed in hazardous areas.
Features and benefits:
- 1 Channel
- 0.4 mA up to 20mA Input – Intrinsically safe in a powered and non-powered state
- Bidirectional HART transmission
- SIL 2 integrity
- Simply DIN Rail mounted
- 3-way electrical isolation
- Low power dissipation & high transmission accuracy
Intrinsic safety:
The 2865340 was designed to be used in intrinsically safe circuits. EX zone 0 and EX zone 20.
Accessories:
Approvals
CE-compliant