SICK Flexi Soft Series Input/Output Module, 8 Inputs, 4 Outputs, 24 V
Technical Document
Specifications
Brand
SickProduct Type
Input/Output Module
Series
Flexi Soft
Sub Type
Input/Output Module
Mount Type
DIN Rail
For Use With
Flexi Soft System
Supply Voltage
24 V
Number of Inputs
8
Number of Outputs
4
Terminal Type
Clamp
Power Rating
3W
Hazardous Area Certification
No
Standards/Approvals
CE, UL
Country of Origin
Germany
Product details
Flexi Soft Extension Unit, FX3-XTIO84002
8 safety inputs, 4 safety outputs and 2 control outputs
Type of safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored
Operating mode switching
Fast shut-off: 9 ms
Maximum output current: 2A
Maximum power consumption: 3W
Response time: < 19ms
Connects to main system using cable gland
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)
Stock information temporarily unavailable.
SR 2,668.13
SR 2,668.13 Each (ex VAT)
SR 3,068.35
SR 3,068.35 Each (inc. VAT)
1
SR 2,668.13
SR 2,668.13 Each (ex VAT)
SR 3,068.35
SR 3,068.35 Each (inc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
SickProduct Type
Input/Output Module
Series
Flexi Soft
Sub Type
Input/Output Module
Mount Type
DIN Rail
For Use With
Flexi Soft System
Supply Voltage
24 V
Number of Inputs
8
Number of Outputs
4
Terminal Type
Clamp
Power Rating
3W
Hazardous Area Certification
No
Standards/Approvals
CE, UL
Country of Origin
Germany
Product details
Flexi Soft Extension Unit, FX3-XTIO84002
8 safety inputs, 4 safety outputs and 2 control outputs
Type of safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored
Operating mode switching
Fast shut-off: 9 ms
Maximum output current: 2A
Maximum power consumption: 3W
Response time: < 19ms
Connects to main system using cable gland
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)