SICK Flexi Soft FX3 Series Safety Controller, 96 Safety Inputs, 48 Safety Outputs, 24 V dc

RS Stock No.: 701-9196Brand: SICKManufacturers Part No.: FX3-CPU000000
brand-logo

Technical Document

Specifications

Brand

Sick

Range

Flexi Soft

Series

FX3

Number of Safety Inputs

96

Number of Safety Outputs

48

Safety Category

4

SIL

SIL 3

Supply Voltage

24 V dc

Contact Current Rating

4 A

IP Rating

IP20

Dimensions

96.5 x 22.5 x 120.8 mm

Depth

120.8mm

Length

96.5mm

Width

22.5mm

Product details

Flexi Soft Safety Controller, Main unit - FX3 CPU000000

Flexi Soft is a programmable and modularly expandable safety controller capable of being integrated into various networks. The main module FX3-CPU is the CPU of the entire system within which all input signals are monitored and processed via the safety logic stored in the memory plug. These signals are then used to switch outputs on the system through the FLEX BUS+ interface which connects all units to one another. The main unit has an RS-232 interface with which the Flexi Soft Designer can upload and change system settings. The RS-232 port can be used for permanent diagnosis (i.e. PLC or HMI) as well.,Functions: EDM, muting, operating mode switching. Logical functions: AND, NOT, OR, XNOR, XOR. Application specific logical functions: operating mode switch, muting, emergency stop, presses, two hand control.,For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a system. The gateways provide I/O Status and Error/Status Messaging. Additionally, non-safety related information can be sent to the Flexi Soft from the network. Each gateway can send and receive at least 50 Bytes of information.

System save in memory plug for a fast installation
Modular expandable (from 12 to 144 in/outputs maximum)
2.5 W power consumption
Intuitive free to download software: Flexi Soft Designer
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

SR 1,664.13

Each (ex VAT)

SR 1,913.75

Each (inc. VAT)

SICK Flexi Soft FX3 Series Safety Controller, 96 Safety Inputs, 48 Safety Outputs, 24 V dc

SR 1,664.13

Each (ex VAT)

SR 1,913.75

Each (inc. VAT)

SICK Flexi Soft FX3 Series Safety Controller, 96 Safety Inputs, 48 Safety Outputs, 24 V dc
Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Sick

Range

Flexi Soft

Series

FX3

Number of Safety Inputs

96

Number of Safety Outputs

48

Safety Category

4

SIL

SIL 3

Supply Voltage

24 V dc

Contact Current Rating

4 A

IP Rating

IP20

Dimensions

96.5 x 22.5 x 120.8 mm

Depth

120.8mm

Length

96.5mm

Width

22.5mm

Product details

Flexi Soft Safety Controller, Main unit - FX3 CPU000000

Flexi Soft is a programmable and modularly expandable safety controller capable of being integrated into various networks. The main module FX3-CPU is the CPU of the entire system within which all input signals are monitored and processed via the safety logic stored in the memory plug. These signals are then used to switch outputs on the system through the FLEX BUS+ interface which connects all units to one another. The main unit has an RS-232 interface with which the Flexi Soft Designer can upload and change system settings. The RS-232 port can be used for permanent diagnosis (i.e. PLC or HMI) as well.,Functions: EDM, muting, operating mode switching. Logical functions: AND, NOT, OR, XNOR, XOR. Application specific logical functions: operating mode switch, muting, emergency stop, presses, two hand control.,For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a system. The gateways provide I/O Status and Error/Status Messaging. Additionally, non-safety related information can be sent to the Flexi Soft from the network. Each gateway can send and receive at least 50 Bytes of information.

System save in memory plug for a fast installation
Modular expandable (from 12 to 144 in/outputs maximum)
2.5 W power consumption
Intuitive free to download software: Flexi Soft Designer
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)