Specifications

Product Type

Interface Converter

Input Signal Type

RS232, RS422, RS485

Output Signal Type

RS485, RS422

Supply Voltage

24 V

Hazardous Area Certification

Ex nA IIC T4 Gc X, AEx nA IIC T4, B, Div 2, IECEx, Groups A, C, ATEX, UL, D, Zone 2

Mount Type

DIN Rail

Maximum Operating Temperature

55°C

Minimum Operating Temperature

0°C

IP Rating

IP20

Signal Conditioner Type

Converter

Standards/Approvals

EN 61000-6-2:2005, EN 61000-4-5, cUL, ATEX, EN 61000-6-4, EN 61000-4-2, EN 61000-4-4, IECEX, EN 61000-4-6, EAC, CE, EN 55011, DNV GL, KC, UL, EN 61000-4-3

Series

PSM

Number of Channels

2

Country of Origin

Germany

Product details

Interface Converter RS-232/RS422, RS-232/RS-485

From Phoneix Contacts, the DIN-Rail mounted PSM-ME-RS232/RS485-P Interface converter is designed to convert RS-232 interface signals bi-directionally to the RS-485 and RS-422 standard. The robust dual-channel converter is a category 3 device designed for installation in zone 2 potentially explosive areas. It meets the requirements of EN 60079-0:2012+A11:2013 and EN 60079-15:2010.

Featuring diagnostic and status indicator LEDs for supply voltage and RS232 data reception and transmission. The PSM-ME-RS232/RS485-P Interface converter offers the user the flexibility to meet the many demands of today’s industrial applications.

Programming

The PSM-ME-RS232/RS485-P signal conditioners are configurable dip switches and slide switches, accessed via opening the housing and sliding out the PCB.

Features and Benefits

• RS-422 4-wire point-to-point operation
• RS-485 2-wire operation, half-duplex
• RS-485 4-wire operation, full-duplex
• Automatic RS-485 transmit/receive changeover
• Transmission speed of 4.8 kbps to 115.2 kbps
• Integrated data indicator for dynamic indication of transmit and receive data
• High-quality 3-way isolation between the power supply, RS-232, and RS-422/RS-485
• Integrated surge protection with transient discharge to the DIN rail

Application Examples

RS-232 to RS-485

The RS-485 standard is employed where more than two devices need to communicate with each other. By converting the RS-232 point-to-point interface to the bus-capable RS-485 standard, up to 32 devices may be networked via a 2-wire cable (semi-duplex) or 4-wire cable (full-duplex).

Possible applications:
· RS-232 master adjustment
· Programming/parameterization connection
· In networking RS-232 devices, the software must ensure devie addressability

RS-232 to RS-422

The RS-422 interface is an interface for point-to-point connections.

Possible applications:
· Interface adaptation to RS-422 devices
· Point-to-point connections of up to 1200 m; for range increase and interference-free transmission of RS-232 signals

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Stock information temporarily unavailable.

SR 3,130.96

SR 3,130.96 Each (ex VAT)

SR 3,600.60

SR 3,600.60 Each (inc. VAT)

Phoenix Contact PSM Series Interface Converter, RS232, RS422, RS485 Input, RS485, RS422 Output, 24 V Supply, Ex nA IIC

SR 3,130.96

SR 3,130.96 Each (ex VAT)

SR 3,600.60

SR 3,600.60 Each (inc. VAT)

Phoenix Contact PSM Series Interface Converter, RS232, RS422, RS485 Input, RS485, RS422 Output, 24 V Supply, Ex nA IIC

Stock information temporarily unavailable.

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Technical Document

Specifications

Product Type

Interface Converter

Input Signal Type

RS232, RS422, RS485

Output Signal Type

RS485, RS422

Supply Voltage

24 V

Hazardous Area Certification

Ex nA IIC T4 Gc X, AEx nA IIC T4, B, Div 2, IECEx, Groups A, C, ATEX, UL, D, Zone 2

Mount Type

DIN Rail

Maximum Operating Temperature

55°C

Minimum Operating Temperature

0°C

IP Rating

IP20

Signal Conditioner Type

Converter

Standards/Approvals

EN 61000-6-2:2005, EN 61000-4-5, cUL, ATEX, EN 61000-6-4, EN 61000-4-2, EN 61000-4-4, IECEX, EN 61000-4-6, EAC, CE, EN 55011, DNV GL, KC, UL, EN 61000-4-3

Series

PSM

Number of Channels

2

Country of Origin

Germany

Product details

Interface Converter RS-232/RS422, RS-232/RS-485

From Phoneix Contacts, the DIN-Rail mounted PSM-ME-RS232/RS485-P Interface converter is designed to convert RS-232 interface signals bi-directionally to the RS-485 and RS-422 standard. The robust dual-channel converter is a category 3 device designed for installation in zone 2 potentially explosive areas. It meets the requirements of EN 60079-0:2012+A11:2013 and EN 60079-15:2010.

Featuring diagnostic and status indicator LEDs for supply voltage and RS232 data reception and transmission. The PSM-ME-RS232/RS485-P Interface converter offers the user the flexibility to meet the many demands of today’s industrial applications.

Programming

The PSM-ME-RS232/RS485-P signal conditioners are configurable dip switches and slide switches, accessed via opening the housing and sliding out the PCB.

Features and Benefits

• RS-422 4-wire point-to-point operation
• RS-485 2-wire operation, half-duplex
• RS-485 4-wire operation, full-duplex
• Automatic RS-485 transmit/receive changeover
• Transmission speed of 4.8 kbps to 115.2 kbps
• Integrated data indicator for dynamic indication of transmit and receive data
• High-quality 3-way isolation between the power supply, RS-232, and RS-422/RS-485
• Integrated surge protection with transient discharge to the DIN rail

Application Examples

RS-232 to RS-485

The RS-485 standard is employed where more than two devices need to communicate with each other. By converting the RS-232 point-to-point interface to the bus-capable RS-485 standard, up to 32 devices may be networked via a 2-wire cable (semi-duplex) or 4-wire cable (full-duplex).

Possible applications:
· RS-232 master adjustment
· Programming/parameterization connection
· In networking RS-232 devices, the software must ensure devie addressability

RS-232 to RS-422

The RS-422 interface is an interface for point-to-point connections.

Possible applications:
· Interface adaptation to RS-422 devices
· Point-to-point connections of up to 1200 m; for range increase and interference-free transmission of RS-232 signals

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more