Technical Document
Specifications
Brand
ParkerProduct Type
Pneumatic Timer
Hazardous Area Certification
Conforming to certificate LCIE 866115X, EExe ll T4
Mount Type
DIN Rail
Minimum Operating Pressure
3bar
Maximum Operating Pressure
8 bar
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
60°C
Standards/Approvals
EN 50014 dated March 1977 (NFC 23514 dated May 1982), EN 50019 dated March 1977 (NFC 23519 dated May 1982)
Product details
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Very Reliable
Long Life Expectancy
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.
Stock information temporarily unavailable.
SR 1,631.77
SR 1,631.77 Each (ex VAT)
SR 1,876.54
SR 1,876.54 Each (inc. VAT)
1
SR 1,631.77
SR 1,631.77 Each (ex VAT)
SR 1,876.54
SR 1,876.54 Each (inc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
ParkerProduct Type
Pneumatic Timer
Hazardous Area Certification
Conforming to certificate LCIE 866115X, EExe ll T4
Mount Type
DIN Rail
Minimum Operating Pressure
3bar
Maximum Operating Pressure
8 bar
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
60°C
Standards/Approvals
EN 50014 dated March 1977 (NFC 23514 dated May 1982), EN 50019 dated March 1977 (NFC 23519 dated May 1982)
Product details
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Very Reliable
Long Life Expectancy
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.