Specifications
Brand
ElestaCoil Voltage
12V dc
Mounting Type
PCB Mount
Contact Configuration
DPST
Number of Poles
2
Coil Resistance
520Ω
Switching Current
6A
Maximum Switching Current AC
6 A
Coil Power
0.27W
Maximum Switching Current DC
6 A
Maximum Switching Voltage DC
250V
Maximum Switching Voltage AC
250V
Terminal Type
Through Hole
Contact Material
Gold Plated
Minimum Operating Temperature
-40°C
Series
SIS 2
Maximum Operating Temperature
+70°C
Maximum Switching Power DC
1.5 kW
Depth
16.6mm
Height
16.5mm
Length
29.2mm
Life
90000Cycles
Maximum Switching Power AC
1.5 kVA
Country of Origin
Switzerland
Product details
Elesta SIS Relays, 2 Contacts
PCB Relay with forcibly guided contacts
Protective seperation between control and load circuit (leakage and creepage distances >10mm)
- EN 50205, type A
-Double and reinforced insulation between the contacts
- Contact mounting: SIS112 1NO/1NC
- Small external dimensions
- Mean coil power 0.27W
- Holding power 0.08 W
- For Railway Applications: EN 50155
SR 110.58
SR 110.58 Each (ex VAT)
SR 127.17
SR 127.17 Each (inc. VAT)
1
SR 110.58
SR 110.58 Each (ex VAT)
SR 127.17
SR 127.17 Each (inc. VAT)
Stock information temporarily unavailable. please contact rs@ae.com.sa for more details.
1
Stock information temporarily unavailable. please contact rs@ae.com.sa for more details.
Technical Document
Specifications
Brand
ElestaCoil Voltage
12V dc
Mounting Type
PCB Mount
Contact Configuration
DPST
Number of Poles
2
Coil Resistance
520Ω
Switching Current
6A
Maximum Switching Current AC
6 A
Coil Power
0.27W
Maximum Switching Current DC
6 A
Maximum Switching Voltage DC
250V
Maximum Switching Voltage AC
250V
Terminal Type
Through Hole
Contact Material
Gold Plated
Minimum Operating Temperature
-40°C
Series
SIS 2
Maximum Operating Temperature
+70°C
Maximum Switching Power DC
1.5 kW
Depth
16.6mm
Height
16.5mm
Length
29.2mm
Life
90000Cycles
Maximum Switching Power AC
1.5 kVA
Country of Origin
Switzerland
Product details
Elesta SIS Relays, 2 Contacts
PCB Relay with forcibly guided contacts
Protective seperation between control and load circuit (leakage and creepage distances >10mm)
- EN 50205, type A
-Double and reinforced insulation between the contacts
- Contact mounting: SIS112 1NO/1NC
- Small external dimensions
- Mean coil power 0.27W
- Holding power 0.08 W