Technical Document
Specifications
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
HWUA
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
35mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Product details
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.
Control of 3 phase networks: phase sequence, phase failure, asymmetry, under and overvoltage with independent settings
Multi function / Multi-voltage product
True RMS measurement
LED status indication
Stock information temporarily unavailable.
Please check again later.
SR 1,354.91
Each (ex VAT)
SR 1,558.15
Each (inc. VAT)
1
SR 1,354.91
Each (ex VAT)
SR 1,558.15
Each (inc. VAT)
1
Technical Document
Specifications
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
HWUA
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
35mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Product details
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.
Control of 3 phase networks: phase sequence, phase failure, asymmetry, under and overvoltage with independent settings
Multi function / Multi-voltage product
True RMS measurement
LED status indication