Crouzet Phase, Voltage Monitoring Relay, SP-NO/NC, 183 → 528V ac

RS Stock No.: 261-892Brand: CrouzetManufacturers Part No.: 84873023
brand-logo
View all in Monitoring Relays

Technical Document

Specifications

Brand

Crouzet

Monitoring Application

Phase, Voltage

Voltage Sensing Range

183 → 528V ac

Contact Configuration

SP-NO/NC

Voltage Sensitivity

Undervoltage

Phase Sensitivity

Phase Failure, Phase Sequence

Time Delay

0.1 → 10s

Dimensions

69 x 17.5 x 92.6mm

Maximum Voltage Sensed

528V ac

Height

92.6mm

Length

69mm

Minimum Voltage Sensed

183V ac

Operating Temperature Range

-20 → +50°C

Minimum Operating Temperature

-20°C

Width

17.5mm

Maximum Operating Temperature

+50°C

Country of Origin

France

Product details

Multi Function Phase Control Relays 17.5mm - C-Lynx

3 phase network control relays monitor: the correct sequence of phases L1, L2, L3, the total phase failure - Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay and Asymmetry rate from 5% to 15% of Under Voltage Relay. LEDs are used for fault signalling, if a fault persists for longer than the threshold crossing delay configured by the operator, the output relay opens and the LED R is extinguished.

"Control of 3 phase networks: phase sequence, phase failure, imbalance (asymmetry), over and under voltage
Range includes mono-function product and multi function product
Multi-voltage from 3 x 208 to 3 x 480 V
True RMS measurement
LED status indication"

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

SR 514.01

Each (ex VAT)

SR 591.11

Each (inc VAT)

Crouzet Phase, Voltage Monitoring Relay, SP-NO/NC, 183 → 528V ac

SR 514.01

Each (ex VAT)

SR 591.11

Each (inc VAT)

Crouzet Phase, Voltage Monitoring Relay, SP-NO/NC, 183 → 528V ac
Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Crouzet

Monitoring Application

Phase, Voltage

Voltage Sensing Range

183 → 528V ac

Contact Configuration

SP-NO/NC

Voltage Sensitivity

Undervoltage

Phase Sensitivity

Phase Failure, Phase Sequence

Time Delay

0.1 → 10s

Dimensions

69 x 17.5 x 92.6mm

Maximum Voltage Sensed

528V ac

Height

92.6mm

Length

69mm

Minimum Voltage Sensed

183V ac

Operating Temperature Range

-20 → +50°C

Minimum Operating Temperature

-20°C

Width

17.5mm

Maximum Operating Temperature

+50°C

Country of Origin

France

Product details

Multi Function Phase Control Relays 17.5mm - C-Lynx

3 phase network control relays monitor: the correct sequence of phases L1, L2, L3, the total phase failure - Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay and Asymmetry rate from 5% to 15% of Under Voltage Relay. LEDs are used for fault signalling, if a fault persists for longer than the threshold crossing delay configured by the operator, the output relay opens and the LED R is extinguished.

"Control of 3 phase networks: phase sequence, phase failure, imbalance (asymmetry), over and under voltage
Range includes mono-function product and multi function product
Multi-voltage from 3 x 208 to 3 x 480 V
True RMS measurement
LED status indication"