Technical Document
Specifications
Brand
CelducMaximum Load Current
40 A
Mounting Type
Panel Mount
Maximum Load Voltage
400 V ac
Minimum Load Voltage
200 V ac
Minimum Control Voltage
0 V
Maximum Control Voltage
10 V dc
Switching Type
Burst Fire Control
Control Voltage Range
0 → 10 V dc
Range
SG5-SWG5
Minimum Load Current
5 mA
Number of Poles
1
Terminal Type
Screw
Output Device
Triac
Relay Type
Full wave pulse controller
Series
SG5-SWG5
Load Voltage Range
200 → 400V ac
Dimensions
100 x 73.5 x 39.5mm
Height
39.5mm
Off State Leakage Current
1 mA
Length
100mm
Operating Temperature Range
-25 → +85°C
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+85°C
Depth
73.5mm
Country of Origin
France
Product details
Phase Angle and Frequency Burst Regulators
SG5 relays with proportional control have an analogue input isolated from the mains allowing a proportional variation of the operating duty cycle at this input through the generation of frequency bursts.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.
Proportional and Power
SR 1,886.63
SR 1,886.63 Each (ex VAT)
SR 2,169.62
SR 2,169.62 Each (inc. VAT)
1
SR 1,886.63
SR 1,886.63 Each (ex VAT)
SR 2,169.62
SR 2,169.62 Each (inc. VAT)
1
Stock information temporarily unavailable.
Please check again later.
Technical Document
Specifications
Brand
CelducMaximum Load Current
40 A
Mounting Type
Panel Mount
Maximum Load Voltage
400 V ac
Minimum Load Voltage
200 V ac
Minimum Control Voltage
0 V
Maximum Control Voltage
10 V dc
Switching Type
Burst Fire Control
Control Voltage Range
0 → 10 V dc
Range
SG5-SWG5
Minimum Load Current
5 mA
Number of Poles
1
Terminal Type
Screw
Output Device
Triac
Relay Type
Full wave pulse controller
Series
SG5-SWG5
Load Voltage Range
200 → 400V ac
Dimensions
100 x 73.5 x 39.5mm
Height
39.5mm
Off State Leakage Current
1 mA
Length
100mm
Operating Temperature Range
-25 → +85°C
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+85°C
Depth
73.5mm
Country of Origin
France
Product details
Phase Angle and Frequency Burst Regulators
SG5 relays with proportional control have an analogue input isolated from the mains allowing a proportional variation of the operating duty cycle at this input through the generation of frequency bursts.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.