Technical Document
Specifications
Brand
CelducMaximum Load Current
40 A
Mounting Type
Panel Mount
Maximum Load Voltage
460 V rms
Minimum Load Voltage
200 V ac
Minimum Control Voltage
0 V
Maximum Control Voltage
10 V dc
Switching Type
Phase Angle
Control Voltage Range
0 → 10 V dc
Range
SG4
Minimum Load Current
10 mA
Number of Poles
1
Terminal Type
Screw
Output Device
Thyristor
Relay Type
Single Phase angle controller
Maximum Turn On Time
10ms
Series
SG4
Load Voltage Range
200 → 400V ac
Dimensions
100 x 73.5 x 39.5mm
Standards Met
CE, EAC
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+85°C
Depth
73.5mm
Height
39.5mm
Off State Leakage Current
5 mA
Length
100mm
Operating Temperature Range
-40 → +85°C
Country of Origin
France
Product details
Phase Angle and Frequency Burst Regulators
SG5 relays with proportional control have an analogue input isolated from the mains allowing a proportional variation of the operating duty cycle at this input through the generation of frequency bursts.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.
Proportional and Power
Stock information temporarily unavailable.
Please check again later.
SR 1,868.15
Each (ex VAT)
SR 2,148.37
Each (inc. VAT)
1
SR 1,868.15
Each (ex VAT)
SR 2,148.37
Each (inc. VAT)
1
Technical Document
Specifications
Brand
CelducMaximum Load Current
40 A
Mounting Type
Panel Mount
Maximum Load Voltage
460 V rms
Minimum Load Voltage
200 V ac
Minimum Control Voltage
0 V
Maximum Control Voltage
10 V dc
Switching Type
Phase Angle
Control Voltage Range
0 → 10 V dc
Range
SG4
Minimum Load Current
10 mA
Number of Poles
1
Terminal Type
Screw
Output Device
Thyristor
Relay Type
Single Phase angle controller
Maximum Turn On Time
10ms
Series
SG4
Load Voltage Range
200 → 400V ac
Dimensions
100 x 73.5 x 39.5mm
Standards Met
CE, EAC
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+85°C
Depth
73.5mm
Height
39.5mm
Off State Leakage Current
5 mA
Length
100mm
Operating Temperature Range
-40 → +85°C
Country of Origin
France
Product details
Phase Angle and Frequency Burst Regulators
SG5 relays with proportional control have an analogue input isolated from the mains allowing a proportional variation of the operating duty cycle at this input through the generation of frequency bursts.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.