Technical Document
Specifications
Brand
Allen BradleySupply Voltage
230V ac
Number of Channels
2
Safety Contacts
2
Function
Safety Monitoring
Reset Method
Automatic & Manual
Range
Guardmaster MSR, Minotaur
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Depth
22.5mm
Series
440R / MSR126.1T
Width
75mm
Performance Level
e
Length
110mm
Country of Origin
Czech Republic
Product details
Rockwell Automation Minotaur MSR126R and MSR126T, Single or Dual Channel Safety Relays
Experience dependable basic fault detection for your control safety system with the Minotaur MSR126R and MSR126T Safety Relays by Rockwell Automation. These 22.5mm relay devices have 2NO (Normally Open) Safety Rated Outputs, which have independent and redundant internal contacts to help ensure the safety command. With these Safety Relays you can prevent risk of damage to machinery and protect personnel from injury, minimising downtime and giving you peace-of-mind.
MSR126R/T: This relay is designed specifically for connection to a single channel safety gate, a single channel e-stop or a light curtain that provides cross fault detection.
MSR126.1R/T: This relay is intended for connection to a dual channel safety gate or e-stop, as it performs cross fault detection across the inputs.
MSR126R and MSR126.1R: These safety relays are made for applications where a monitored manual reset is necessary. Monitored manual reset requires the use of a manually operated normally open momentary switch to activate the outputs.
MSR126T and MSR126.1T: These units are intended for use in applications which demand automatic/manual resets. This type of reset allows a jumper across the S33-S34 circuit, and so does not perform output monitoring.
Features and Benefits:
Stop category 0
Cross fault monitoring
Monitored manual or automatic reset
Cat. 4 per EN954-1
2 Safety contacts N.O.
Single/dual channel operation
Stock information temporarily unavailable.
Please check again later.
SR 894.04
Each (ex VAT)
SR 1,028.15
Each (inc. VAT)
1
SR 894.04
Each (ex VAT)
SR 1,028.15
Each (inc. VAT)
1
Technical Document
Specifications
Brand
Allen BradleySupply Voltage
230V ac
Number of Channels
2
Safety Contacts
2
Function
Safety Monitoring
Reset Method
Automatic & Manual
Range
Guardmaster MSR, Minotaur
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Depth
22.5mm
Series
440R / MSR126.1T
Width
75mm
Performance Level
e
Length
110mm
Country of Origin
Czech Republic
Product details
Rockwell Automation Minotaur MSR126R and MSR126T, Single or Dual Channel Safety Relays
Experience dependable basic fault detection for your control safety system with the Minotaur MSR126R and MSR126T Safety Relays by Rockwell Automation. These 22.5mm relay devices have 2NO (Normally Open) Safety Rated Outputs, which have independent and redundant internal contacts to help ensure the safety command. With these Safety Relays you can prevent risk of damage to machinery and protect personnel from injury, minimising downtime and giving you peace-of-mind.
MSR126R/T: This relay is designed specifically for connection to a single channel safety gate, a single channel e-stop or a light curtain that provides cross fault detection.
MSR126.1R/T: This relay is intended for connection to a dual channel safety gate or e-stop, as it performs cross fault detection across the inputs.
MSR126R and MSR126.1R: These safety relays are made for applications where a monitored manual reset is necessary. Monitored manual reset requires the use of a manually operated normally open momentary switch to activate the outputs.
MSR126T and MSR126.1T: These units are intended for use in applications which demand automatic/manual resets. This type of reset allows a jumper across the S33-S34 circuit, and so does not perform output monitoring.
Features and Benefits:
Stop category 0
Cross fault monitoring
Monitored manual or automatic reset
Cat. 4 per EN954-1
2 Safety contacts N.O.
Single/dual channel operation