Power Quality Analysers
Power quality analysers are used to measure electric power signals ensuring the measurement of the electrical signal, monitoring the operation of the electrical power system is working within that power. This is important as electrical equipment will not work to capacity or malfunction without the right electrical power. RS work with major electrical test and power measurement equipment manufac...
Showing 1-20 of 36 products
RS Pro
3000A
9999kW
-
600V
±0.5 % ± 5 Digits
1 %
LCD
AC Current, AC Voltage, AC Wattage, Harmonic, Total Harmonic Distortion
-
-
-
-
AA
IPM3005
-
-
-
-
-
50 Hz, 65Hz
-
-
-
-
-
RS Pro
3000A
9999kW
-
600V
±0.5 % ± 5 Digits
1 %
LCD
AC Current, AC Voltage, AC Wattage, Harmonic, Phase Angle, Power Factor, Total Harmonic Distortion
-
RS232C
-
Battery
AA
IPM6300
-
65 Hz
130mm
43mm
-10°C
65Hz
-
450g
+50°C
80 x 43 x 130mm
80mm
RS Pro
1500A
9999kW
3
600V
±0.5 % ± 5 Digits
±0.5 % ± 5 Digits
LCD
AC Current, AC Voltage, AC Wattage, Crest Factor, Harmonic, Phase Angle, Power Factor, Total Harmonic Distortion
-
RS232C
-
Battery
AA
IPM6200
-
-
210mm
35.6mm
-10°C
50 Hz, 60Hz
-
640g
+50°C
62 x 35.6 x 210mm
62mm
RS Pro
3000A
9999kW
-
600V
±0.5 % ± 5 Digits
1 %
LCD
AC Current, AC Voltage, AC Wattage, Harmonic, Total Harmonic Distortion
-
USB
-
-
AA
IPM3005
-
-
-
-
-
50 Hz, 65Hz
-
-
-
-
-
RS Pro
999.9A
999.9kW
3
999.9V
±0.3 % ± 10 Digits
±0.5 % ± 15 Digits
LCD
AC Current, AC Voltage, AC Wattage, Frequency, Harmonic, Phase Angle, Power Energy, Power Factor, Three Phase Sequency Detection
-
USB
-
Battery
AA
IPM3600N
-
-
235mm
54mm
0°C
60Hz
-
-
+50°C
116 x 54 x 235mm
116mm
RS Pro
1500A
9999kW
3
600V
±0.5 % ± 5 Digits
±0.5 % ± 5 Digits
LCD
AC Current, AC Voltage, AC Wattage, Crest Factor, Harmonic, Phase Angle, Power Factor, Total Harmonic Distortion
-
RS232C
-
Battery
AA
IPM6200
-
-
210mm
35.6mm
-10°C
50 Hz, 60Hz
-
640g
+50°C
62 x 35.6 x 210mm
62mm
RS Pro
3000A
9999kW
-
600V
±0.5 % ± 5 Digits
1 %
LCD
AC Current, AC Voltage, AC Wattage, Harmonic, Phase Angle, Power Factor, Total Harmonic Distortion
-
RS232C
-
Battery
AA
IPM6300
-
65 Hz
130mm
43mm
-10°C
65Hz
-
450g
+50°C
80 x 43 x 130mm
80mm
Chauvin Arnoux
10000 A ac, 5000 A dcA ac
10 MW, 10 MVAR, 10 MVAmW
1, 3
1000 V ac, 1200V dc
±(0.5 % + 200 mV)
±(0.5 % + 2 mA)
Colour, TFT LCD
Cos, Current, DPF, Energy values, Flicker, Frequency, Harmonics, Inrush, PF, Power values, Tan, Transients, Unbalance, Voltage
IEC 610101
USB
-
Battery, Mains
Rechargeable NiMH
CA 8331
13 h
40 Hz
55mm
180mm
0°C
70Hz
-
1.9kg
+50°C
240 x 180 x 55mm
240mm
Chauvin Arnoux
10000 A ac, 5000 A dcA ac
10 MW, 10 MVAR, 10 MVAmW
1, 3
1000 V ac, 1200V dc
±(0.5 % + 200 mV)
±(0.5 % + 2 mA)
Colour, TFT LCD
Cos, Current, DPF, Energy values, Flicker, Frequency, Harmonics, Inrush, PF, Power values, Tan, Transients, Unbalance, Voltage
EN50160, IEC 61000-4-30
USB
-
Battery, Mains
Rechargeable NiMH
CA8336
13 h
40 Hz
55mm
180mm
0°C
70Hz
-
1.9kg
+50°C
240 x 180 x 55mm
240mm
Fluke
6000A
1500mW
3
1000V dc
±0.1 %
-
Touchscreen
-
-
-
8GB
-
-
1773/BASIC
-
42.5 Hz
280mm
62mm
-10°C
69Hz
-
2.1kg
+50°C
28 x19 x 6.2cm
190mm
Fluke
6000A
1500mW
3
1000V dc
±0.1 %
-
Touchscreen
-
-
-
8GB
-
-
1775/BASIC
-
42.5 Hz
280mm
62mm
-10°C
69Hz
-
2.1kg
+50°C
28 x19 x 6.2cm
190mm
Fluke
6000A
1500mW
3
1000V dc
±0.1 %
-
-
Current, Power, Voltage
EN50160
Bluetooth, USB, Wireless
-
Battery
Li-Ion
1777/BASIC
-
50 Hz
62mm
190mm
-10°C
60Hz
-
2.1kg
+50°C
28 x 19 x 6.2cm
280mm
Chauvin Arnoux
100 A ac, 100 A ac/dc, 200 A ac, 1000 A ac, 1300 A ac/dc, 10000 A ackA
10 MW, 10 MVAR, 10 MVAmW
1, 3
1000 V ac, 1200V dc
0.1 %
0.50%
Colour LCD Touch Screen
Cos, Current, DPF, Energy values, Flicker, Frequency, Harmonics, Inrush, PF, Power values, Transients, Unbalance, Tan, Voltage
EN50160, IEC 61000-4-30
SD, USB, WIFI, RJ45
64GB
Battery, Mains
Li-Ion
CA8345
10h
42.50 Hz
55mm
200mm
-5°C
69Hz
-
1.9kg
45°C
200 x 285 x 55mm
285mm
Fluke
6000A
1500mW
3
1000V dc
±0.1 %
-
-
Current, Power, Voltage
EN50160
Bluetooth, USB, Wireless
-
Battery
Li-Ion
1777
-
50 Hz
62mm
190mm
-10°C
60Hz
-
2.1kg
+50°C
28 x 19 x 6.2cm
280mm
Chauvin Arnoux
6500 A ac, 1700 A dcA
9999 kW, 9999 kVar, 9999kVA
1, 3
600V ac
±0.5% +2 Digits
±0,5% +1 Digit
Backlit LCD
Current, Energy, Frequency, Harmonics, Inrush Current, Phase rotation, Power, Resistance (winding), RPM, Temperature, Voltage
IEC62301
RS232, USB
-
Battery, Mains
AA
CA 8220
20h
40 Hz
60mm
108mm
0°C
69Hz
-
880g
+50°C
211 x 108 x 60mm
211mm
Chauvin Arnoux
10000 A ac, 5000 A dcA ac
10 MW, 10 MVAR, 10 MVAmW
1, 3
1000 V ac, 1200V dc
±(0.5 % + 200 mV)
±(0.5 % + 2 mA)
Colour, TFT LCD
Cos, Current, DPF, Energy values, Flicker, Frequency, Harmonics, Inrush, PF, Power values, Tan, Transients, Unbalance, Voltage
EN50160, IEC 61000-4-30
USB
-
Battery, Mains
Rechargeable NiMH
CA 8333
13 h
40 Hz
55mm
180mm
0°C
70Hz
-
1.9kg
+50°C
240 x 180 x 55mm
240mm
Chauvin Arnoux
100 A ac, 100 A ac/dc, 200 A ac, 1000 A ac, 1300 A ac/dc, 10000 A acA
10 MW, 10 MVAR, 10 MVAW
1, 3
1000 V ac, 1200V dc
±(0.5 % + 200 mV)
±(0.5 % + 2 mA)
Colour, TFT LCD
Cos, Current, DPF, Energy values, Flicker, Frequency, Harmonics, Inrush, PF, Power values, Transients, Unbalance, Tan, Voltage
EN50160, IEC 61000-4-30
USB
-
Battery, Mains
Rechargeable NiMH
CA 8436
13 h
40 Hz
180mm
250mm
0°C
70Hz
-
3,7kg
+50°C
270 x 250 x 180mm
270mm