Druck UPS-II, 20mA Current Loop Calibrator - RS Calibration

RS Stock No.: 182-5507Brand: DruckManufacturers Part No.: UNO-UPS-II-1841
brand-logo
View all in Loop Calibrators

Technical Document

Specifications

Brand

Druck

Absolute Maximum Current Measurement

20mA

Calibrated

RSCAL

Best Accuracy

±0.05 %

Resolution

10 μA

Battery Type

AA

Battery Life

64 h

Power Source

Battery

Dimensions

77 x 124 x 21mm

Weight

285g

Height

21mm

Length

77mm

Maximum Operating Temperature

+50°C

Minimum Operating Temperature

-10°C

Width

124mm

Model Number p

UPS-II

Country of Origin

United Kingdom

Product details

Druck Digital Loop Calibrator - UPS II

Forming part of Druck's essential range, the UPS II loop calibrator is a high quality, handheld, pocket-sized process instrument. The loop calibrator has been created and designed for checking and simulating 2-wire transmitters and stroking valves. You'll commonly find the calibrator being used within applications in the process industry, but with its ease of portability and microprocessor-based electronics, it can be taken out in the field to be used in many other commercial and industrial applications.

Features & Benefits

• The output currents are adjustable to a resolution of 10 micro amps within both source and transmitter simulations
• Auto-stepping for hands-free calibration
• Auto-ramp cycling for endurance tests
• Sources and reads in milliamps (mA)
• Has an internal loop power of 24 Volts (voltage)
• Reads and powers two-wire transmitters
• Simulates and reads dp-transmitters
• Fixed calibration currents
• Fixed currents for valve stroking, enabling users to check for correct seating and operation of the valve
• The dimension measurements of the loop calibrator are L124 x W77 x D21 mm
• The calibrator can display readings in percentage of a 4-20 mA or 0-20 mA span
• If the loop calibrator has a loop mismatch, low power supply (battery), or is over range it will be indicated via the digital interface
• Features an operating temperature of 15°F to 120°F (-10°C to 50°C)
• Weight: 285 g included batteries
• Housing: High impact ABS
• Batteries: 4 x 1.5 V AA
• Battery life: Sources 12 mA 13 hours, Measures 64 hours

What's included with the kit?

• A leather case and carry strap
• User guide
• Test leads
• Set of alkaline batteries - 1.5V (voltage) AA
• Spare fuse

You may be interested in

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

SR 3,652.18

Each (ex VAT)

SR 4,200.01

Each (inc. VAT)

Druck UPS-II, 20mA Current Loop Calibrator - RS Calibration

SR 3,652.18

Each (ex VAT)

SR 4,200.01

Each (inc. VAT)

Druck UPS-II, 20mA Current Loop Calibrator - RS Calibration
Stock information temporarily unavailable.
You may be interested in

Technical Document

Specifications

Brand

Druck

Absolute Maximum Current Measurement

20mA

Calibrated

RSCAL

Best Accuracy

±0.05 %

Resolution

10 μA

Battery Type

AA

Battery Life

64 h

Power Source

Battery

Dimensions

77 x 124 x 21mm

Weight

285g

Height

21mm

Length

77mm

Maximum Operating Temperature

+50°C

Minimum Operating Temperature

-10°C

Width

124mm

Model Number p

UPS-II

Country of Origin

United Kingdom

Product details

Druck Digital Loop Calibrator - UPS II

Forming part of Druck's essential range, the UPS II loop calibrator is a high quality, handheld, pocket-sized process instrument. The loop calibrator has been created and designed for checking and simulating 2-wire transmitters and stroking valves. You'll commonly find the calibrator being used within applications in the process industry, but with its ease of portability and microprocessor-based electronics, it can be taken out in the field to be used in many other commercial and industrial applications.

Features & Benefits

• The output currents are adjustable to a resolution of 10 micro amps within both source and transmitter simulations
• Auto-stepping for hands-free calibration
• Auto-ramp cycling for endurance tests
• Sources and reads in milliamps (mA)
• Has an internal loop power of 24 Volts (voltage)
• Reads and powers two-wire transmitters
• Simulates and reads dp-transmitters
• Fixed calibration currents
• Fixed currents for valve stroking, enabling users to check for correct seating and operation of the valve
• The dimension measurements of the loop calibrator are L124 x W77 x D21 mm
• The calibrator can display readings in percentage of a 4-20 mA or 0-20 mA span
• If the loop calibrator has a loop mismatch, low power supply (battery), or is over range it will be indicated via the digital interface
• Features an operating temperature of 15°F to 120°F (-10°C to 50°C)
• Weight: 285 g included batteries
• Housing: High impact ABS
• Batteries: 4 x 1.5 V AA
• Battery life: Sources 12 mA 13 hours, Measures 64 hours

What's included with the kit?

• A leather case and carry strap
• User guide
• Test leads
• Set of alkaline batteries - 1.5V (voltage) AA
• Spare fuse

You may be interested in