Allen Bradley Guardmaster 440-R Series Input/Output Module, 1 Inputs, 6 Outputs, 24 V dc, 4NO/2NC

RS Stock No.: 447-5802Brand: Allen Bradley GuardmasterManufacturers Part No.: 440R-E23098
brand-logo
View all in Safety IO Modules

Technical Document

Specifications

Range

Minotaur

Series

440-R

Type

Input/Output Module

For Use With

440R MSR100

Supply Voltage

24 V dc

Normal State Configuration

4NO/2NC

Number of Inputs

1

Number of Outputs

6

Power Rating

1.5 W

Mounting Style

DIN Rail

Dimensions

99 x 22.5 x 114.5 mm

Terminal Type

Screw

Country of Origin

Germany

Product details

Minotuar MSR132E Expansion Unit

Designed to be an expansion relay for use with the Minotaur safety relays. Typically used in safety system applications where additional output switching connections are needed to help shut down a manufacturing process, properly and safely.
Can be connected as a single channel (1 N/C) or dual channel (2 N/C) input configuration.

Safety Category 4/3 per EN 954-1
Stop Category 0 or 1
4 safety contacts NO
2 auxiliary contacts NC
1 monitoring contact NC
Single channel input

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

SR 1,126.03

Each (ex VAT)

SR 1,294.93

Each (inc. VAT)

Allen Bradley Guardmaster 440-R Series Input/Output Module, 1 Inputs, 6 Outputs, 24 V dc, 4NO/2NC

SR 1,126.03

Each (ex VAT)

SR 1,294.93

Each (inc. VAT)

Allen Bradley Guardmaster 440-R Series Input/Output Module, 1 Inputs, 6 Outputs, 24 V dc, 4NO/2NC
Stock information temporarily unavailable.

Technical Document

Specifications

Range

Minotaur

Series

440-R

Type

Input/Output Module

For Use With

440R MSR100

Supply Voltage

24 V dc

Normal State Configuration

4NO/2NC

Number of Inputs

1

Number of Outputs

6

Power Rating

1.5 W

Mounting Style

DIN Rail

Dimensions

99 x 22.5 x 114.5 mm

Terminal Type

Screw

Country of Origin

Germany

Product details

Minotuar MSR132E Expansion Unit

Designed to be an expansion relay for use with the Minotaur safety relays. Typically used in safety system applications where additional output switching connections are needed to help shut down a manufacturing process, properly and safely.
Can be connected as a single channel (1 N/C) or dual channel (2 N/C) input configuration.

Safety Category 4/3 per EN 954-1
Stop Category 0 or 1
4 safety contacts NO
2 auxiliary contacts NC
1 monitoring contact NC
Single channel input