Iso-tech IDM203 Bench multimeter
|
This image is representative of the product range
|
|
RS Stock No.
|
212-871
|
|
Manufacturer
|
RS
|
|
Manufacturers Part No.
|
IDM203
|
Production packaging option
66 in stock in the UK.
Stock Information correct at 29/07/2010 12:42 PM
-
This item is from our Extended Range
Please note:
- The Extended Range includes both electronic components and process control automation products that have been sourced from Allied Electronics, our sister company in the USA.
- Please allow extra time for delivery.
- Because of different lead times, these items may be invoiced separately from other items in the same order.
- Extended Range items are only available online.
Production packaging offer
- Supplied in industry standard packaging
- For automated insertion in the production environment
- Flexible order quantities, order in multiples of 1
- Each
Also available in standard packaging
|
|
Attributes
|
Attribute Type
|
Attribute Value
|
|
Display Counts
|
4000
|
|
Display Type
|
LCD
|
|
Highest Voltage Range
|
600Vdc/600 Vac
|
|
Highest Current Range
|
10 A ac/dc
|
|
USB Connection
|
No
|
|
RS 232 Connection
|
No
|
|
GPIB Connection
|
No
|
Overview
ISO-TECH IDM 203/205 Bench Multimeters
ISO-TECH IDM 203//205 Bench Multimeters
Two battery/mains 4000 count bench multimeters with analogue bargraph. Capable of measuring voltage, current, resistance, frequency and capacitance.
IDM 203//205 features:
- Analogue bargraph updates 20 times per second
Frequency measurement to 1MHz
Capacitance ranges from 4nF f.s.d. to 40μF f.s.d.
Input protection to 600V r.m.s. min. on all ranges
HRC fuse protected current ranges
Delayed hold feature allows automatic capture of measurements
Relative function stores the displayed reading as a reference value
Max/Min mode records the highest and lowest readings
Autoranging with manual override
Independently approved to meet IEC 1010-1 (safety standard) 600V Cat. II.
Lead storage facility in case
ac/dc dual power sources
IDM 205 additional features:
- True rms measurement on a.c. ranges to avoid inaccuracies on non-sinusoidal waveforms
Memory feature allows displayed reading to be stored for later recall
| Technical Specification |
| DC Voltage Accuracy | ±0.75% / ±0.3 % | DC Current Accuracy | ±1.5% / 0.8% |
| DC Voltage Digits | +2D | DC Current Digits | + 4D |
| DC Voltage Lowest Range | 400mV | DC Current Lowest Range | 4mA |
| DC Voltage Highest Range | 600V | DC Current Highest Range | 10A |
| DC Voltage Lowest Resolution | 0.1μV | DC Current Lowest Resolution | 1μA |
| AC Voltage Accuracy | ±1.5% / 1% | AC Current Accuracy | ±2.5% - 0.8% |
| AC Voltage Digits | +5 D | AC Current Digits | +5D |
| AC Voltage Lowest Range | 4V | AC Current Lowest Range | 4mA/200mA |
| AC Voltage Highest Range | 600 V | AC Current Highest Range | 10A |
| AC Voltage Lowest Resolution | 0.1μV | AC Current Lowest Resolution | 0.1μA / 1μA |
| AC Voltage Max Frequency | 1kHz | AC Current Max Frequency | 1kHz |
| | | Resistance Accuracy | ±2.5% / 1.5% |
| | | Resistance Digits | +5D |
Supplied With