Transformer PCB 4VA 2x15V


The 3D viewer requires the Java Runtime Environment (JRE) and for Java to be enabled on your system.

Please Register or Log In to Download the 3D image files
RS Stock No. 201-6962
Manufacturer Block
Manufacturers Part No. FL 4/15
RoHS Status RoHS Certificate of Compliance
qty Price Each
1 P.O.A
10 P.O.A
25 P.O.A
50 P.O.A
100 P.O.A
23 in stock in the UK.
This stock information was correct at 18/05/2012 12:51 PM. This information is updated daily so availability may vary at time of order placement.

Technical data sheets

Click here to access technical data sheets in PDF format online.

Attributes

Attribute Type Attribute Value
VA Rating 4
Input Voltage 115; 230V ac
Output Voltage 2 x 15V ac
Output Current 0.13A
Regulation Typ. 26%
Efficiency Typ. 58%
Secondary V off load approx. on load V x 1.43V
Weight 145g
Dimensions L x W x H 53 x 44 x 19.6mm
Iron Loss 1.2W

Overview

PCB Mounting Low Profile 115 / 230Vac Primary

  • Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
    Twin secondary windings for series or parallel connection
    Low profile compact design
    Vacuum epoxy resin moulded to UL94-V0 rating
    Double section glass fibre reinforced polyamide bobbins
    100% electrical and flash tested
    Low inter-winding capacitance
    Low radiated noise
    Extra fixing holes for secure board mounting
    Standard: EN60742, VDE 0551, IEC 61558
Selection Guide
VA Rating Fixing Centres   Pin Configuration        
  C1 C2 P1 P2 S1 S2 A
4 VA 37.5 47.5 15 10 25 5 35
6 VA 37.5 47.5 15 10 25 5 35
10 VA 50 62.5 16 15 26 10 45
14 VA 50 62.5 16 15 26 10 45
18 VA 50 62.5 16 15 26 10 45
24 VA 50 62.5 16 15 26 10 45
30 VA 50 62.5 16 15 26 10 45
42 VA 60 75 27 15 37 10 53.5
52 VA 60 75 27 15 37 10 53.5
Isolation Primary to secondary 5kV
  Primary to primary 1kV
  Secondary to secondary 250V
Protection Class 2
Insulation Class E (120°C) Class A (105°C)
Max. Ambient Temperature +40°C
Pin Diameter (mm) 0.8 mm
Fixing: mechanical fixings can be supplemented by 4 self tapping screws (no. 4 x 9.5mm max. on the 2VA to 30VA transformers and M3 on the 42 and 52VA transformers) using holes mounted in the corners of the case
Note: For conformance reasons, transformer with 2 x 24V outputs should not have their secondaries connected in series
 

Note

Transformer with 2 x 24V outputs are not VDE, SEV approved.

Approvals

Standards

VD 61 558

Caution

Warning

Supplied With

Range Overview

Encapsulated - Laminated FL series (Dual output)

Note

Approvals

Standards

Caution

Warning

Supplied With


Found an error?  Print page   Send page to a colleague

RS International Distributor Network
This RS authorised distributor website has been developed by Catalogue Solutions Ltd under licence by RS Components Ltd.
Arab Engineers For Engineering Services, P.O. Box 88392, Tahliah Trading Centre, Al Hamdan Street, Riyadh 11662, Saudi Arabia

For general inquiries: +966 4633117